2.Basic Technical Information

2. Основная техническая информация

Number of units and power output of power plant covered by this specification are according to the above mentioned table (table B2). The power plant shall consist of all auxiliaries and station service equipment.


Количество блоков и выходной мощности электростанции, охватываемых этой спецификацией в соответствии с вышеупомянутой таблицой (В2). Электростанция состоит из вспомогательного и станционного сервисного оборудования.
The power plant shall be operating with natural gas or heavy fuel oil or any combination of these fuels and heavy fuel oil as start up fuel.

Электростанция будет работать на природном газе или мазут или любой комбинации этих видов топлива и мазута в качестве топлива запуска.

Preliminary analysis of fuels delivered to power plant is given bellow. The exact analysis will be provided by client at design stage.
Предварительный анализ топлива, поставленного на электростанции, приводится ниже. Точный анализ будет предоставлен Заказчиком на стадии проектирования.

3-Environmental Protection

3. Защита окружающей среды

Regulations of Iranian Environmental Protection Organization (I.E.P.O) shall be strictly followed for design purposes .In the absence of such regulations, other standards which are mentioned shall be followed.

Для целей проектирования должно быть строго соблюдено Положение иранской Организации по охране окружающей среды (I.P.P.O). В случае отсутствия таких предписаний, могут быть применены другие стандарты, которые упомянуты ниже.

3.1 Effluent waste water
For waste water effluent limitation, regulations of I.E.P.O indicated in the table below shall be followed.

3.1. Сточные воды
Нормы по очистке сточных вод должны соответствовать стандартам I.E.P.O., приведенным ниже в таблице.

Iranian Environmental Protection Organization (I.E.P.O)

Standard and rules for maximum allowable quantity of pollutants in the waste water drained into various resources.

Иранская организация по охране окружающей среды (I.E.P.O)

Нормы и правила для максимально допустимого количества загрязняющих веществ в сточных водах, дренируемых в различные источники
TABLES

Iranian Environmental Protection Organization (I.E.P.O)

Standard and rules for maximum allowable quantity of pollutants in the waste water drained into various resources.

ТАБЛИЦЫ

Организация по защите окружающей среды Ирана (I.E.P.O)

Стандарты и нормы максимально разрешенного количества загрязнения в сточных водах, отводимых в различные ресурсы (емкости??)


Item No.

Pollutants

Drain to Surface Water

Drain to underground Resources

Agricultural & Irrigation Uses

1

Al

5 p.p.m

5 p.p.m

5 p.p.m

2

Ba

5 "

1 "

1 "

3

Be

0.1 "

1 "

0.5 "

4

B

2 "

1 "

1 "

5

Cd

0.1 "

0.1 "

0.05 "

6

Ca

75 "

-

-

7

Cr6+

0.5 "

1 "

1 "

8

Cr3+

2 "

2 "

2 "

9

Co

1 "

1 "

0.05"

10

Cu

1 "

1 "

0.2 "

11

Fe

3 "

3 "

3 "

12

Li

2.5 "

2.5 "

2.5 "

13

Mg

100 "

100 "

100 "

14

Mn

1 "

1 "

1 "

15

Hg

trace

trace

trace

16

Mo

0.01 "

0.01 "

0.01"

17

Ni

2 "

2 "

2 "

18

Pb

1 "

1 "

1 "

19

Se

1 "

0.1 "

0.1 "

20

Ag

1 "

0.1 "

0.1"

21

Zn

2 "

2 "

2 "

22

V

0.1 "

0.1 "

-

23

Radio actives

0.0 "

0.0 "

0.0 "

24

As

0.1 "

0.1 "

0.1 "

25

Cl (free)

1 "

1 "

0.21 "

26

Cl-

600 *

600 **

600

27

F

2.5 "


2 "

2 "

28

P

6 "

6 "

-

29

CN

0.5 "

0.1 "

0.1 "

30

C6H50H

1 "

trace

1 "

31

CH2O

1 "

1 "

1 "

32

NH4

2.5 "

1 "

-

33

NO2-

10 "

10 "

-

34

NO3-

50 "

10 "

-

35

SO4--

400 *

400 **

500 "

36

SO3--

1 "

1 "

1 "

37

Total suspended solid (T.S.S)

40 (momentary 60)

-

100 "

38

Settleable (S.S)

0 "

-

-

39

Total dissolved solid (T.D.S.)

*

**

-

40

Oil & Grease

10 "

10 "

10 "

41

B.O.D

30 (momentary 50)

30 (momentary 50)

100 "

42

C.O.D

60 (momentary 100)

60 (momentary 100)

200 "

43

Dissolved oxygen D.O

2 "

-

2 "

44

Detergents

1.5 "

0.5 "

0.5 "

45

Turbidity

50 "

-

50 "

46

Color (Color unit)

75

75

75

47

Temperature

***

-

-

48

PH

6.5-8.5

5-9

6-8.5

49

Coliform (Digestional)

400No./m1

400 No./m1

400 No./m1

50

Coliform (M.P.N.)

1000

1000

1000

51

Nematode

-

-

****







Item No.

Загрязнитель

Сток на поверхность воды


Сток в недра

Агроирригационное использование

1

Al

5 p.p.m

5 p.p.m

5 p.p.m

2

Ba

5 "

1 "

1 "

3

Be

0.1 "

1 "

0.5 "

4

B

2 "

1 "

1 "

5

Cd

0.1 "

0.1 "

0.05 "

6

Ca

75 "

-

-

7

Cr6+

0.5 "

1 "

1 "

8

Cr3+

2 "

2 "

2 "

9

Co

1 "

1 "

0.05"

10

Cu

1 "

1 "

0.2 "

11

Fe

3 "

3 "

3 "

12

Li

2.5 "

2.5 "

2.5 "

13

Mg

100 "

100 "

100 "

14

Mn

1 "

1 "

1 "

15

Hg

trace

trace

trace

16

Mo

0.01 "

0.01 "

0.01"

17

Ni

2 "

2 "

2 "

18

Pb

1 "

1 "

1 "

19

Se

1 "

0.1 "

0.1 "

20

Ag

1 "

0.1 "

0.1"

21

Zn

2 "

2 "

2 "

22

V

0.1 "

0.1 "

-

23

Radio actives

0.0 "

0.0 "

0.0 "

24

As

0.1 "

0.1 "

0.1 "

25

Cl (free)

1 "

1 "

0.21 "

26

Cl-

600 *

600 **

600

27

F

2.5 "


2 "

2 "

28

P

6 "

6 "

-

29

CN

0.5 "

0.1 "

0.1 "

30

C6H50H

1 "

trace

1 "

31

CH2O

1 "

1 "

1 "

32

NH4

2.5 "

1 "

-

33

NO2-

10 "

10 "

-

34

NO3-

50 "

10 "

-

35

SO4--

400 *

400 **

500 "

36

SO3--

1 "

1 "

1 "

37

Total suspended solid (T.S.S)

40 (momentary 60)

-

100 "

38

Settleable (S.S)

0 "

-

-

39

Total dissolved solid (T.D.S.)

*

**

-

40

Oil & Grease

10 "

10 "

10 "

41

B.O.D

30 (momentary 50)

30 (momentary 50)

100 "

42

C.O.D

60 (momentary 100)

60 (momentary 100)

200 "

43

Dissolved oxygen D.O

2 "

-

2 "

44

Detergents

1.5 "

0.5 "

0.5 "

45

Turbidity

50 "

-

50 "

46

Color (Color unit)

75

75

75

47

Temperature

***

-

-

48

PH

6.5-8.5

5-9

6-8.5

49

Coliform (Digestional)

400No./m1

400 No./m1

400 No./m1

50

Coliform (M.P.N.)

1000

1000

1000

51

Nematode

-

-

****





* Discharged wastewater should not increase the amount of chloride, sulfate and T.D.S. of receiving source, more than 10 percent, around 200m from discharge point.

** Chloride, sulfate and T.D.S. of discharged wastewater should not be more than 10%, relative to the consumed water.

*** Discharged wastewater should not increase or decrease the temperature of receiving source, more than 3°C, around 200m from discharge point.

**** Number of nematode should not be more than one per liter if treated municipal wastewater is used for irrigation of agricultural products which are not cooked for consumption
*Содержание хлорида, сульфатов в сточных водах и степень минерализации не должна превышать 10% по отношению хим.составу среды места отведения для радиуса 200 м от места сброса.
** Содержание хлорида, сульфатов и степени минерализации не должно превышать 10% по отношению к объему сточной воды
*** Температура сточной воды не должна превышать/быть ниже более чем на 3 градуса Цельсия, чем температура места ее отведения в радиусе 200 м от места сброса

**** Количество круглых червей не должно превышать одного на литр обработанной муниципальной воды, используемой для полива с/х продуктов, которые будут потребляться без обработки
1   2   3   4   5   6   7   8   9   ...   18

Похожие:

Thermal electric power generation iconIran thermal electric power generation

Thermal electric power generation icon68A, Malookhtinskiy pr., of. 307, St. Petersburg 195112 Russia
Фрезерные и токарные оц фирмы haas (сша), создание учебных классов на базе станков haas, листообрабатывающее оборудование фирм finn-power,...

Thermal electric power generation iconПособие по курсу How to Build a Startup Business Model Generation Canvas
Также здесь приведены копи-пасты всех «домашних заданий» по этому курсу. Именно поэтому часть пособия идет на английском языке

Thermal electric power generation iconКласс Фамилия Имя Отчество
Форма представления (Макет/ чертежи/ презентация Power Point/ люительсктй фильм/ мультфильм или другое)

Thermal electric power generation iconReliable dc power Over Existing Category 5 Cabling
Поддерживает беспроводные точки доступа d-link или аналогичные системы с питанием от постоянного тока 5 в или 12 В

Thermal electric power generation iconBandar abbas steam power plant project (4x350 mw)
Том 4/1 график выполнения работ, график технической информации (механическое и вспомогательное оборудование)

Thermal electric power generation iconУтверждаю директор фгуп «нии «Квант»
В соответствии с п. 2 приложения д по ишва. 025 2016 «смк. Положение о закупках товаров, работ, услуг предприятия» вносятся изменения...

Thermal electric power generation iconКонкурсная документация
Для справок обращаться к Организатору конкурса: ведущему специалисту отдела управления закупками Урываевой Евгении Владимировне,...

Thermal electric power generation iconРуководство по проведению тренинга «Эффективная коммуникация»
Приветствие. Представление тренера, темы и целей тренинга. Тема и цели тренинга могут быть заранее зафиксированы на флип-чарте или...

Thermal electric power generation iconВ извещении о проведении запроса цен (запроса котировок) в электронной...
МК. Положение о закупках товаров, работ, услуг предприятия вносятся изменения в извещение и документацию о запросе цен (запроса котировок)...

Вы можете разместить ссылку на наш сайт:


Все бланки и формы на filling-form.ru




При копировании материала укажите ссылку © 2019
контакты
filling-form.ru

Поиск